(1)清理并平整施工场地;
(2)标出第一遍夯点位置,并测量场地高程;
(3)起重机就位,夯锤置于夯点位置;
(4)测量夯前锤顶高程;
(5)将夯锤起吊到预定高度,开启脱钩装置,待夯锤脱钩自由下落后,放下吊钩,测量锤顶高程,若发现因坑底倾斜而造成夯锤歪斜时,应及时将坑底整平。
(6)重复步骤(5),按设计规定的夯击次数及控制标准,完成一个夯点的夯击;
(7)换夯点,重复步骤(3)至(6),完成第一遍全部夯点的夯击;
(8)用推土机将夯坑填平,并测量场地高程;
(9)在规定的间隔时间后,按上述步骤逐次完成全部夯击遍数,最后用低能量满夯,将场地表层松土夯实,并测量夯后场地高程。