预应力管桩的桩芯满灌混凝土有什么施工规范?
【解答】关于预应力管桩灌注混凝土只有两个部位,一个是桩尖端得持力层部位,也就是桩尖板上2米范围内,一般设计要求灌注2米深的C25混凝土,主要用于保护桩尖钢板不被地下水给腐蚀;另外一个部位就是桩顶(入承台范围)以下1.5米-1.0米范围内,一般是灌注C35微膨胀细石混凝土,其功能主要是确保桩与承台的锚固,同时内安放4根20或22的钢筋。上述两个一般设计图纸或广东省的地方标准都有的,你可以去查查,同时如果设计图不完善,可以再图纸会审时提出,将来作为增加变更工程进行工程结算哦。
Application of Pipe Pile Composite Foundation Engineering
下一篇NDRC: Major Reforms to Be Rolled Out in Due Course, Urbanization Plan to Be Revised

2024-09-29 13335 0

2024-09-20 13336 0

2024-09-20 13180 0

2024-09-19 12457 0

Lize City Air Terminal Underground Main Structure Nearing Completion: Maximum Transfer Walk Under 4 Minutes After Operation

Anti-seepage Curtain for Main Lock Pit of CSCEC Port Shenqiu Double-Line Lock Project Completed on Schedule

All Pile Foundations Completed on Quanzhou Baiqi Channel